Quantitative Analysis of the Water–Energy Nexus in Office Buildings in a Semi-Arid Climate: Evaluating Statistical Relationships and Identifying Consumption Hotspots through Calibrated Simulation

Document Type : Original Research

Authors
Department of Environmental Engineering, Faculty of Civil Engineering, K. N. Toosi University of Technology, Tehran, Iran
Abstract
Traditional siloed resource management in the building sector, which neglects interdependencies between water and energy systems, may result in the transfer of resource pressures across different consumption pathways. This study aimed to quantitatively analyze the water–energy nexus in a six-story office building with a total floor area of 2040 m² located in Tehran, Iran. A numerical building model was developed in DesignBuilder and calibrated and validated using three years of actual utility consumption data (2022–2024) in accordance with ASHRAE Guideline 14. The monthly nexus intensity analysis indicated that water and electricity consumption exhibited synchronous seasonal patterns during the cooling period, particularly in August, associated with the operation of the water-cooled cooling system. A multiple linear regression model based on the ordinary least squares method, with a coefficient of determination (R²) of 87.3%, revealed a statistical association between variations in water consumption and energy carriers in the studied case. The Nexus Contribution Factor, proposed as a relative indicator of the contribution of cooling-related water consumption to total annual water use, indicated that 68.9% of annual water consumption occurred during the cooling period. In addition, simulation-based analysis demonstrated that the cooling tower accounted for the dominant share of water consumption in the cooling system. The findings highlight the importance of integrated water and energy assessments in buildings equipped with water-cooled cooling systems.
Keywords
Subjects